Motor: ME II 3 - 460W, 230V
Immersion depth: 1000 mm (sealless)
Suitable for 200l drum emptying Undervoltage release
prevents unexpected start-up of the pump after power failure. Recommended
when pumping hazardous liquids.
conditionally safe to run dry
Description:
The Pump Set is suitable for low viscosity, flammable and combustible hydrocarbons. Perfectly suited for the removal or decanting of solvents.
- Media examples: Ethanol, gasoline, butanol, isopropanol, kerosene, methanol and petroleum.etc.
- Pump tube equipped with Lutz original hand wheel
- Suitable for filling or transferring alternative fuels, oils, flammable liquids
Features & Advantages
- Optionally with electric or compressed air drive
- No lubricants and therefore no contamination of the pumped medium by lubricants
- Highly resistant noble carbon shaft bearing
- Maintenance without special tools
- Seal modules of the seal-less (DL) pump can be replaced
- Approved according to ATEX directive 2014/34/EU, category 1/2
Suitable media: | Petroleum, Methanol, Kerosin, Isopropanol, Butanol, Benzin, Ethanol |
Pump tube (material): | Niro (Edelstahl) |
Impeller (material): | ETFE (ethylene-tetrafluorethylene copolymer) |
Static seal (material): | no seals in contact with the medium |
Mechanical seal (material): | no seals in contact with the medium |
Bearing (material): | Edelkohle |
Drive shaft (material): | Edelstahl (1.4571) |
Delivery rate (up to max. l/min)*: | 95 |
Delivery rate with Nozzle (up to max. l/min)*: | 60 |
Delivery head (up to max. mWS)*: | 14 |
Fluid temperature (max °C): | 100 |
density (up to kg/dm³): | 1.6 |
Viscosity (up to mPas): | 350 |
Conveyor wheel shape / drive type: | Radial-flow impeller |
Seal type: | Sealless (SL) |
Immersion length (mm): | from 1000 mm |
Immersion tube diameter (up to mm): | 41 |
Thread (inch) outside: | 1 1/4" |
Schlauchlänge (mm): | 2000 |
Explosion protection: | Yes |
Type of drive: | Electric |
Output (W): | 460 |
Voltage (V): | 230 |
Frequency (Hz): | 50 |
Protection type: | IP54 |
Version: | mit Unterspannungsauslöser |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20 °C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil. ** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter