Delivery rate: 24 m³/h
Note: For excess lengths over 1000 mm, the article number
0118-419 is always recorded for every 100 mm or part thereof.
Example with a nominal dimension of 1500 mm , the additional price 0118-419 5x is recorded
Description:
High performance, compact dimensions, low weight - everything fits with the Lutz B6. The pump shaft is protected by a shaft guide tube against possible "attack" of the pumped medium. Perfectly suited for pumping and draining of neutral and aggressive liquids with low solids content.
- on request also available in special immersion depths of 1000 - 3000 mm
- Design according to the single pipe principle
- Application examples: For conveying and circulating chemicals and solutions in surface treatment, chemical industry and water treatment, etc.
Features & Advantages
- Wide range of applications
- No risk of leakage at the bottom outlet due to safe product removal
- Low wear
- Stationary installation possible via flange
- Also for small container openings
Pump tube (material): | PP (polypropylene) |
Impeller (material): | PP (polypropylene) |
Static seal (material): | FPM (fluororubber) |
Mechanical seal (material): | Keramik,FPM,HC |
Drive shaft (material): | Hastelloy C (2.4610) |
Fördermenge (bis max. m³/h)*: | 24 |
Delivery head (up to max. mWS)*: | 9 |
Fluid temperature (max °C): | 50 |
Viscosity (up to mPas): | 4000 |
Conveyor wheel shape / drive type: | Radial-flow impeller |
Seal type: | Mechanical seal (MS) |
Immersion tube diameter (up to mm): | 166 |
Thread (inch) outside: | 2 3/4" |
Version: | Vertical |
Type: | B6/15 PP |
* The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20 °C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil. ** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter